أنا  Alan Said Taha Said Ahmad


Lecturer

التخصصات

Medical physics

التعليم

M.Sc. Degree

physics من University of Zakho

2012

M.Sc. Degree

physics من University of Zakho

2003

اللقب العلمي

Lecturer

2016-06-15

Assitant Lecturer

2012-02-01

جوائز

2013-03

 2013

Letter of Appreciation

2013-03
2013

This honor is for my high teaching quality and academic activities including students' feedback for the academic year 2013-2014.

 2013

البحوث العلمية

INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS (القضية : 11) (الحجم : 9)
Features Optimization for ECG Signals Classification

Abstract—A new method is used in this work to classify ECG beats. The new method... See more

Abstract—A new method is used in this work to classify ECG beats. The new method is about using an optimization algorithm for selecting the features of each beat then classify them. For each beat, twenty-four higher order statistical features and three timing interval features are obtained. Five types of beat classes are used for classification in this work, atrial premature contractions (APC), normal (NOR), premature ventricular contractions (PVC), left bundle branch (LBBB) and right bundle branch (RBBB). Cuttlefish algorithm is used for feature selection which is a new bio-inspired optimization algorithm. Four classifiers are used within CFA, Scaled Conjugate Gradient Artificial Neural Network (SCG-ANN), K-Nearest Neighborhood (KNN), Interactive Dichotomizer 3 (ID3) and Support Vector Machine (SVM). The final results show an accuracy of 97.96% for ANN, 95.71% for KNN, 94.69% for ID3 and 93.06% for SVM, these results were tested on fourteen signal records from MIT-HIH database, where 1400 beats were extracted from these records.

 2018-11
International Journal of Medical Research and Health Sciences (القضية : 5) (الحجم : 7)
How the Size of a Meteorite and Asteroid on the Moon and Planets is Related to the Size of the Crater

Craters occur when an objects like Asteroids, Comets and Meteorites hits onto the surfaces of... See more

Craters occur when an objects like Asteroids, Comets and Meteorites hits onto the surfaces of Moon and Planets and their impact has became a major geological process. The objective of the project is to investigate how the size of a Meteorite and Asteroid on the Moon and Planets is related to the size of impact crater. We started with a two round stone of different mass and size covered slightly with a layer of a viscous mud fluid as a fragmentation were dropped at variable height onto the flour. However, we have used a layer of sprinkles as a mineral diversity of the surface impacted. We have measured the diameter, depth and the Ejecta distance of the crater each time, there were three trails for each stone drop height. The results shows that, the crater diameter and the crater depth increased as the height and mass of the ball drop increased in addition of increasing Ejecta distance.

 2018-05
International Journal of Medical Research and Health Sciences (القضية : 4) (الحجم : 7)
Ischemic Heart-Stroke: Resting ECG Changes in Patients of Duhok in Iraq

Electrocardiography passes on information regarding the electrical function of the heart, by changing the state... See more

Electrocardiography passes on information regarding the electrical function of the heart, by changing the state of its constituent waves, namely the P, QRS, and T-waves which represent one cardiac cycle. The amplitude and interval of P-QRS-T segment determine the function of the heart. Cardiac arrhythmia demonstrates a state of abnormal electrical activity in the heart which is a risk for humans. Currently, onsets of cerebrovascular disease of ischemic nature have electrocardiographic changes, in those patients who had no primary heart disease. We estimated the prevalence of electrocardiographic changes for being of noteworthy one. The aim of this study presents analyses cardiac disease in electrocardiogram (ECG) signals for cardiac arrhythmia which leads to ischemic heart - stroke utilizing investigation of resulting ECG normal and abnormal wave forms. In results 75 of Patient group about (58.67%) were males.

 2018-04
Sylwan (القضية : 3) (الحجم : 162)
Noising - Denoising of Signal Analysis of Electrocardiography (ECG)

Electrocardiographic is for the finding and diagnostic of abnormal cardiac rhythms. It assists in the... See more

Electrocardiographic is for the finding and diagnostic of abnormal cardiac rhythms. It assists in the analysis of the reason for chest torment, and the best possible utilization of early medication in myocardial dead tissue relies on it. It can help with the conclusion of the reason for tipsiness, syncope, and breathlessness. Currently, there is a personal computer-based investigation which utilizes certain signal processing to analyze a patient in view of ECG recording. Noise dependably debases the nature of ECG signal, preprocessing of electrocardiograph is utilized for denoising electrocardiogram signal. Investigation of ECG signal gives data about the status of the heart. ECG signal is a biomedical signal that provides information about the electrical activities of the heart. Different noises of high frequencies and low frequencies are debased with ECG signal that may lead to wrong interpretations. To avoid this problem, we utilize different ECG signal denoising techniques. Applications of the denoising system is essential for the precise analysis of cardiovascular issues like Fast Fourier Transforms, Wavelet Transform, and so on and have been utilized for the location of cardiac diseases. In this paper, we have given an overview of Noising - Denoising of signal analysis of human electrocardiographs.

 2018-03
International Journal of Medical Research and Health Sciences (القضية : 3) (الحجم : 7)
Denoising of Arrhythmia ECG Signals

This study is about using the genetic algorithm (GA) with wavelet transform (WT) for Arrhythmia... See more

This study is about using the genetic algorithm (GA) with wavelet transform (WT) for Arrhythmia Electrocardiogram (ECG) signal denoising purposes. The WT is a time-frequency signal analysis, and the GA is an optimization technique based on survival of the best solution using the maximized or minimized fitness value obtained from the fitness function. In this study, the parameters of WT are used as inputs for the GA for denoising the input signal that is corrupted by white Gaussian noise and gives an output of as fitness value. The input corrupted signal will pass through decomposition process to extract approximation and details coefficients, then thresholding the details coefficients using a threshold value in order to remove the noise, and finally reconstruction of the signal using the approximation and denoised details coefficients. The results of denoising ECG Arrhythmia records were compared with other studies.

 2018-03
International Journal of Astronomy (القضية : 2) (الحجم : 5)
How the Size of a Meteorite and Asteroid on the Moon and Planets is Related to the Size of the Crater

Craters occur when an objects like Asteroids, Comets and Meteorites hits onto the surfaces of... See more

Craters occur when an objects like Asteroids, Comets and Meteorites hits onto the surfaces of Moon and Planets and their impact has became a major geological process. The objective of the project is to investigate how the size of a Meteorite and Asteroid on the Moon and Planets is related to the size of impact crater. We started with a two round stone of different mass and size covered slightly with a layer of a viscous mud fluid as a fragmentation were dropped at variable height onto the flour. However, we have used a layer of sprinkles as a mineral diversity of the surface impacted. We have measured the diameter, depth and the Ejecta distance of the crater each time, there were three trails for each stone drop height. The results shows that, the crater diameter and the crater depth increased as the height and mass of the ball drop increased in addition of increasing Ejecta distance.

 2016-02
Advances in Materials Physics and Chemistry (القضية : 9) (الحجم : 5)
Fabrication ofDyeSensitized Solar Cell Based on Titanium Dioxide (TiOz)

The DyeSensitized Solar Cell (DSSC) plays an important role because of low material cost, ease... See more

The DyeSensitized Solar Cell (DSSC) plays an important role because of low material cost, ease of production and high conversion efficiency as compared to other thin-film solar cell technologies. The main objective is to create and find the best configuration of the solar cell based on materials that are inexpensive and highly efficient in solar energy conversion and subsequently test the efficiency of dye sensitized titanium dioxide solar cell. We begin the process with two glass plates coated with Fluorine tin oxide (FTO). Titanium dioxide is applied to the conductive side of one plate and the other plate is coated with graphite. Adye is adsorbed on to the TiOzlayer and then the plates are sandwiched together. Adrop ofiodide electrolyte is then added between the plates. The tests carried out indoors under a lamp emitting all wavelengths inthe visible spectrum were not found to provide consistent data due to substantial heating of the cell. The outdoor tests carried out in natural sunlight exhibited steady voltage at much higher level. Future research will involve the incorporation of quantum dots instead of the organic dye as a sensitizer. Quantum dots have the advantages ofproviding tunable band gaps and the ability to absorb specific wavelength.

 2015-09
Chemistry & Materials Science (القضية : 4) (الحجم : 6)
Measure the bulk etch rate using the time-diameter method

The present work measured the bulk etch rate (VB ) of solid state nuclear track... See more

The present work measured the bulk etch rate (VB ) of solid state nuclear track detector by taking the diameter time measurement of alpha particle in CR-39 detector. The values of the track diameter have been found by using TRACK-TEST program from Yu et al. function and Brun et al. function with different energies of alpha particles. The results showed that the time-diameter (t-d) method gave good results of the bulk etch rate (VB ) and these values were (1.705 and 1.72) μm·hr-1. They showed good agreement with the values measured by using the other methods, and it was a simple method because it required getting diameters of the tracks in the detector with the etching time.

 2015-04
Advances in Materials Physics and Chemistry (القضية : 4) (الحجم : 5)
The Effect of Doped Indium on the Electrical and Optical Properties of (Se0.7Te0.3)1−xInx Thin Films

In-doped (Se0.7Te0.3) thin films (In: 0, 0.05, and 0.08wt%) with thickness of (150 ± 25... See more

In-doped (Se0.7Te0.3) thin films (In: 0, 0.05, and 0.08wt%) with thickness of (150 ± 25 nm) have been deposited on glass substrates by chemical vapor deposition by using selenium, tellurium and indium whose purity is (99.99%) compound alloy. The electrical and optical properties of the thin films were analyzed. The effects of In-doping concentration on the thermoelectric properties of the thin films were investigated by room-temperature measurement of the See beck coefficient and electrical resistivity. The thermoelectric power factor shows the best result at 0.05wt% in doping. The See beck coefficients are positive with increasing in doping concentration from 0 to 0.08wt%. And the thin films show p-type conduction. For optical properties, the transmission of all samples was approximated to 90%.

 2015-04
Materials Sciences and Applications (القضية : 2) (الحجم : 6)
A New Method to Determine the Maximum Value of the Track Length of Alpha Particle in CR-39 Detector

The aim of this paper is to determine the maximum values of the track length... See more

The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program.

 2015-02

الاطاريح

2019-08-18
(Ph.D) Cardiac Arrhythmia Classifications by Neural Network Using ECG Features and The Effects of Ischemic-Heart Stroke

The aim of this study is to achieve two major goals. The first is to... See more

The aim of this study is to achieve two major goals. The first is to find the frequency of ECG changes of in parameters (such as; Ventricular rate, PR interval, QRS duration, and QRS axis) as a cross-sectional study in Duhok governorate. The second is to find a new way to increase the accuracy percentage of classifying arrhythmia heartbeats using a new feature selection approach.

 2019
2011-10-01
(MSc) - ASSESSMENT OF THE EFFICIENCY CHANGES OF ABDUCTOR POLLICIS BREVIS MUSCLE UNDER THE EFFECTS OF DIFFERENT PHYSICAL PARAMETERS BY USING EMG

In this study, motor conduction of median nerve of abductor pollicies brevis muscle has been... See more

In this study, motor conduction of median nerve of abductor pollicies brevis muscle has been externally electrical activated and surface electrodes of silver –sliver chloride type are used to detect the response (latency period, duration of action potential, action potential amplitude, and action potential area). 252 subjects participated in the test; then, 50 normal volunteers selected irrespective to the gender according to the requirements of the test (all of them right handed, of normal body temperature (37 ± 1), from Erbil city residence with no complains of abnormality abductor pollicies brevis muscle and they have no history of diabetes). The volunteers selected within the age range of (30-36 years). It has been found that the mean latency period is (3.5 ± 0.47 ms); the mean duration time is (10.3 ± 1.68 ms); the mean action potential amplitude is (10.1 ± 1.95 mV), and the mean action potential area is (50.6 ± 8.92 mVms). In comparison with different previous works, it can be concluded that our work is agreed with the main conclusions of others in primary factors, and then our results can be used as a pioneer research to assess the efficiency of abductor pollicies brevis muscle activities during and after muscle physiotherapeutic treatment.

 2011

ورش العمل

University of Zakho
2013-09
E-Learning System Design: Teacher-Student Websites

E-learning System Design Workshop E-learning System Design Workshop Teacher-Student Websites

 2013